Shopping security
Configured for Specific Technical Task in System/Network Name, the Allen-Bradley 1440-TPS02-01RB (1440-TPS02-01RB Position Measurement Module) provides direct physical/electrical execution. This hardware processes dual-channel AC-LVDT sensor inputs to execute real-time linear displacement monitoring, including axial thrust position, casing expansion, differential expansion, and valve positioning across rotating machinery platforms.
| Parameter | Specification |
| Model | 1440-TPS02-01RB |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 0.26 kg (0.56 lbs) |
| Dimensions | 97 mm x 94 mm x 94 mm |
| Operating Temp | -20 to +65 deg C |
| Power Consumption | 24 VDC nominal / 200 mA current draw / 5.28 W maximum |
| Channels | 2 independent AC-LVDT input channels |
| Analog Outputs | 2 channels, 4-20 mA linear output |
| Relay Outputs | 1 DPDT control relay output for alarm/shutdown execution |
| Networks | DeviceNet communication network, RS-232 serial port |
| Mounting Architecture | 1440-TB-B terminal base mounting configuration |
The position measurement module interfaces directly with integrated automation topologies via DeviceNet and RS-232 serial physical layers. Internal logic operations maintain deterministic networks parameters to transmit digitized position metrics across the backplane bus communication velocity framework without data phase lag. The hardware features specific I/O density scaling options through its modular terminal base architecture, allowing parallel distribution of the 4-20 mA analog feedback loops to secondary process control systems. Firmware flash compatibility protocols guarantee that internal diagnostic registers and self-test execution structures sync natively with overarching plant asset management software profiles.
Q: How does the module handle a loss of backplane bus communication velocity on the DeviceNet network?
A: The onboard DPDT control relay operates independently of the digital network communication status. If a DeviceNet bus failure occurs, the internal logic executes pre-configured fail-safe state actions based on local hardware thresholds derived from the direct AC-LVDT physical inputs.
Q: Can the 1440-TPS02-01RB module be removed from the terminal base under live operating voltage?
A: Removal under power is restricted unless the local atmosphere is verified to be free of volatile gas concentrations. Disconnecting the module interrupts the 4-20 mA feedback loops and causes an immediate open circuit on the DPDT relay contact path, which can trigger an uncommanded machinery shutdown.