Shopping security
Configured for safety logic execution in Planar4/HIMatrix systems, the HIMA 42400 (42400 Logic Function Module) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | 42400 |
| Brand | HIMA |
| Origin | Germany |
| Module Type | Logic Function Module / Safety PLC |
| Safety Rating | IEC 61508 SIL 3 |
| Processing Architecture | Dual-channel redundant logic processor |
| Diagnostic Coverage | >99% fault detection |
| Response Time | < 10 ms cycle time |
| Operating Voltage | 24 VDC nominal (18-32 VDC range) |
| Communication Protocols | Modbus RTU, PROFIBUS DP, EtherNet/IP |
| Programming Environment | SILworX (IEC 61131-3 compliant) |
| Operating Temp | -40 to +70 deg C |
| Protection Class | IP20 |
| Power Consumption | 15 W typical |
| Dimensions | Standard Planar4 rack / DIN rail module footprint |
| Weight | 0.5 kg typical |
The 42400 logic function module incorporates a dual-channel redundant logic processor configuration certified to satisfy IEC 61508 SIL 3 parameters. Real-time operations yield greater than 99% internal diagnostic fault detection coverage, triggering an immediate fail-safe state execution upon detection of asymmetrical data processing states or communication frame timeouts. Galvanic isolation circuits shield the core computational matrices from external electrical transients across the I/O terminals, forcing all active safety logic outputs to a de-energized low state to guarantee absolute process mitigation under active trip conditions.
Q: Does the 42400 logic module support hot-swap capabilities under live rack operating conditions?
A: Yes. The hardware interface allows online hot-swapping within redundant architectural configurations, permitting module extraction and replacement without dropping system power or halting the active safety process logic.
Q: What are the primary communication protocols supported by the integrated hardware ports for distributed interface options?
A: The physical data layers are equipped to handle Modbus RTU, PROFIBUS DP, and EtherNet/IP protocols, allowing real-time data monitoring and diagnostic transfers to supervisor platforms.
Q: What action does the internal watchdog execute if the internal logic execution cycle exceeds the 10 ms threshold?
A: An internal hardware watchdog monitors loop execution duration. If the cycle time breaches the maximum parameter, the module initiates a hard reset and automatically commands all outputs to default to their pre-defined fail-safe state execution.
Ships within 48 hours · Estimated delivery Jun 21 - Jun 26