20% OFF shipping at jfccivils.com on orders over $79 + up to 10% OFF products
jfccivils.com
home > 16-Ch Field Termination Assembly | New Honeywell FC-TSGASH-1624 > 16-Ch Field Termination Assembly | New Honeywell FC-TSGASH-1624
download picture
16-Ch Field Termination Assembly | New Honeywell FC-TSGASH-1624Product Overview The Honeywell FC TSGASH 1624 serves as a high integrity, 16 channel Safe Digital Output field termination assembly for the Safety Manager SC (S300 IOTA) ecosystem. This module bridges the Safety Manager controller and field actuators, converting logic demands into precise 24 VDC control signals. It drives critical devices such as solenoids, interposing relays, and emergency shutdown valves in hazardous environments. We supply this
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Honeywell FC-TSGASH-1624 serves as a high-integrity, 16-channel Safe Digital Output field termination assembly for the Safety Manager SC (S300 IOTA) ecosystem. This module bridges the Safety Manager controller and field actuators, converting logic demands into precise 24 VDC control signals. It drives critical devices such as solenoids, interposing relays, and emergency shutdown valves in hazardous environments. We supply this component as 100% Brand New and Original, ensuring your safety-instrumented system (SIS) maintains its SIL3 rating and operational integrity.

Technical Specifications

Attribute Specification Value
Model Number FC-TSGASH-1624 / FC-TSGASH-1624P
Channel Count 16 Independent Digital Outputs
Output Voltage 24 VDC Nominal
Max Switching Current Up to 2 A per channel
Safety Certification SIL3 (IEC 61508 Compliant)
Isolation Channel-to-channel and channel-to-bus
Operating Temperature –40°C to +85°C
Diagnostics Built-in line monitoring and fault detection
Hot-swap Support Yes
Dimensions 22.5 cm x 10.8 cm x 8.5 cm
Weight 0.52 kg

Engineering Advantages

  • High-Density Actuation: The 16-channel design maximizes I/O density within the S300 IOTA rack. This allows engineers to manage extensive valve arrays and safety interlocks from a single module, effectively reducing cabinet footprint and total installation costs.

  • SIL3 Safety Integrity: Every channel undergoes rigorous diagnostic testing to meet IEC 61508 SIL3 requirements. The module ensures that critical safety actions—such as isolating a fuel line—execute without fail, even in complex process scenarios.

  • Active Line Monitoring: Integrated diagnostics perform continuous checks for open circuits and shorted wiring. The module detects field-side faults immediately, providing real-time feedback to the controller to prevent "fail-to-danger" conditions.

  • Galvanic Signal Isolation: Robust isolation barriers protect the internal system backplane from field-side transients and electromagnetic interference (EMI). This prevents a localized electrical fault at a field actuator from cascading through the safety rack.

  • Extreme Environmental Endurance: Engineered for the toughest industrial sites, the module operates across a broad thermal spectrum from –40°C to +85°C. This capability permits installation in unheated remote instrument enclosures (RIE) in harsh geographic regions.

  • Simplified Maintenance: Full hot-swap support allows technicians to replace the module under power. This feature eliminates the need for process shutdowns during routine hardware maintenance, ensuring 24/7 system availability.

FAQs

  • Can the FC-TSGASH-1624 drive high-current solenoids?

    Yes. Each of the 16 channels supports up to 2 A of switching current. This high capacity allows the module to drive most industrial 24 VDC solenoids and actuators directly without needing additional interposing relays.

  • Does this module require a specific IOTA base?

    The FC-TSGASH-1624 integrates specifically with the S300 IOTA (Input Output Termination Assembly) architecture within the Honeywell Safety Manager SC system. Always verify the mechanical compatibility of your mounting base before installation.

  • What is the significance of the "P" suffix found on some versions?

    The "P" typically indicates specific packaging or revision levels designed for global distribution (e.g., via DHL/FedEx). Mechanically and electrically, the FC-TSGASH-1624 and FC-TSGASH-1624P function identically within the safety loop.

  • How does the module handle short circuits in the field?

    The module features built-in overcurrent protection and diagnostics. If it detects a short circuit, it isolates the affected channel and reports a fault to the Safety Manager, protecting the rest of the module from damage.

16-Ch Field Termination Assembly | New Honeywell FC-TSGASH-1624

Item no : 7120830201
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches