20% OFF shipping at jfccivils.com on orders over $79 + up to 10% OFF products
jfccivils.com
home > PSXX2 PowerShield DCC Solid-State Power District Circuit Breaker -- 2-Block, 0-10 Amps per Block > PSXX2 PowerShield DCC Solid-State Power District Circuit Breaker -- 2-Block, 0-10 Amps per Block
download picture
PSXX2 PowerShield DCC Solid-State Power District Circuit Breaker -- 2-Block, 0-10 Amps per BlockThe PSXX series is a product of Larry Maier's years of research and experience into problems dealing with false overloads that cause premature shut down of DCC Boosters and other Circuit Breakers. These false overloads are caused by large capacitors used in sound systems, decoders and lighted passenger cars. The overload appears as a short circuit until the capacitors are charged. The PSXX Series determines if the load is a true short or just an
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The PSXX series is a product of Larry Maier's years of research and experience into problems dealing with false overloads that cause premature shut down of DCC Boosters and other Circuit Breakers. These false overloads are caused by large capacitors used in sound systems, decoders and lighted passenger cars. The overload appears as a short circuit until the capacitors are charged. The PSXX Series determines if the load is a true short or just an overload due to a discharged capacitor.                                  



  • Advanced Circuit Design limits current to selected current value before circuit opens regardless of severity of fault

 

  • Current Limiting will charge sound decoders without exceeding booster current capability

 

  • Default Current Limit/Trip Current 2 amperes will work correctly for most layouts.

 

  • Select Trip current values 1 – 10 in integer steps (1, 2, 3, …., 10) using CV 49

 

  • Jumper Select Current limits of 1, 2, 3, or 4 amperes

 

  • PSXX circuit boards are perforated with score lines so you can physically separate and divide PSXX-2, & PSXX-3 into individual PSXX-1 units if needed.

 

  • Power On/Off by DCC: Turn on/off output track power with your DCC Throttle!

 

  • Manual or Automatic Reset: Automatic reset: Breaker tries to reset every 2 seconds. Manual reset: Once the breaker trips, it remains off, ensuring complete isolation of the faulty block. The breaker is reset either by a switch or by a DCC command.

 

  • All Solid State Operation: Fast, solid state design with reliable quiet action.

 

  • Adaptive Load Reset: Electronically determines if the overload is a real short or due to excess capacitance in sound decoders or lighted passenger cars.

 

  • Auto Stop with DCC Reset: A photocell can be connected to a PSXX input. Normally, covering the photocell will not cause any action. If the photocell is armed with a DCC command, the PSXX will turn off the next time the photocell is covered. A DCC command can restore the track power when desired.

 

  • Photo Cell Controlled Block Power Off: Stop position control and occupancy detection for hidden tracks.

 

  • Block Detection: Either a photo cell or block current draw can be used to detect a train in a block and to trigger a Block Occupied output. The current trigger level is programmable.

 

  • Block Occupied Trip point can be automatically set to compensate for current flow in unoccupied block

 

  • Very Low Voltage Drop: Total breaker on resistance is less than 0.060 ohms, so the PSXX has a very low voltage drop even at high currents. Better than detectors that use a diode voltage drop.

 

  • Programmable Power Up Status: When power is applied to the layout, the PSXX can be set to always turn on, always remain off [power on as needed by DCC command], or to use the power status present when the layout was last shut down.

 

  • Outputs for LED Indicators: Remote LEDs can be added to monitor the input/output power and the status.

 

  • Network Feedback: Isolated outputs designed to provide Block Occupied, Block Shorted, and Power Status to a discrete interface for remote display or computer control. Will work with Digitrax LocoNet, NCE Cab Bus, ESU ECoS, and Lenz XpressNet interfaces.

 

  • System Reset: CV63=42 sets all CVs and addresses to original factory values.

 

  • Output for Audio Alert: An audible sounder can be added to the PSXX to provide an audible alert if there is a short.

 

  • No Power Supply Needed: The PSXX uses the track DCC power to supply its operating power. Each PSXX draws less than 0.04 amperes.

 

  • Easy to Install: With 4 mounting holes sized for a #6 screw.

 

  • Flash Programmable: The PSXX firmware can be updated by Tony’s Train Exchange as new features become available or if older units need to be matched to a recent purchase.

 

  • Discrete Input allows on/off control of track voltage for yard or other track section isolation. Compatible with any system that has a relay or isolated transistor control output including LCC, WiFi, etc. or can be used with manual toggle switch.

 

  • 4 Indicator LEDs: Booster power (green), Block power (green), Block shorted (red), Block current limiting (blue)

 

  • +5V and Ground Outputs for powering LEDs, no resistors needed

 

  • Power On Status can be on, off (yard or staging sections), or status at power down.

 

  • DCC Accessory command control on any Accessory address 1 – 2042.

PSXX2 PowerShield DCC Solid-State Power District Circuit Breaker -- 2-Block, 0-10 Amps per Block

Item no : 7761496773
sold recently : Login >>
US$ 99.99
Pay in 4 interest-free payments of $25.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 21 - Jun 26

Enjoy 20% off shipping

US$ 99.99

1-11

US$ 89.99

12-35

US$ 69.99

36-59

US$ 59.99

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches