Shopping security
Configured for field wiring interface execution in CENTUM VP/CS 3000 systems, the Yokogawa ATD5S-00 (ATD5S Terminal Block Unit) provides direct physical/electrical execution. The hardware serves as the physical interface connecting external discrete or analog field components directly to the 32-channel system I/O modules via a pressure-clamp termination structure.
| Parameter | Specification |
|---|---|
| Model | ATD5S-00 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.2 kg |
| Dimensions | 114 x 32.6 x 60.5 mm |
| Operating Temp | -20 to +55 deg C |
| Power Consumption | Passive device (0 W internal consumption) |
| Channel Capacity | 32 signal points per block |
| Maximum Voltage | 250 VAC/DC |
| Current Rating | 5 A maximum continuous per common bus |
| Dielectric Strength | 1500 VAC for 1 minute |
| Insulation Resistance | Minimum 100 MΩ at 500 VDC |
The Yokogawa ATD5S-00 manages high-density signal distribution without the use of onboard surge absorbers, operating as a direct pass-through terminal matrix. The insulation resistance of 100 MΩ ensures electrical separation between adjacent signal paths, preventing cross-talk and crosstalk-induced signal degradation in paired analog or high-frequency digital loops. Channel-to-channel isolation parameters are dictated by the paired active module, while the physical base unit delivers a dielectric strength of 1500 VAC to protect the internal FIO baseplate components against common-mode voltage spikes arising from external field grounding differentials.
Q: How does the lack of internal surge absorbers affect installation choices for the -00 suffix variant?
A: The -00 suffix designates a standard terminal assembly without onboard surge suppression components. It must be deployed in environments where external lightning/surge protection is already established on the signal loops, or for general-purpose digital and analog signal circuits where high-voltage transients are not anticipated.
Q: What are the continuous electrical current limitations when multiple channels are loaded?
A: While individual terminals accommodate standard field signals, the common return bus path features a strict hardware limit of 5 A maximum continuous current. Exceeding this thermal threshold will result in structural degradation of the flame-retardant engineering plastic housing.
Ships within 48 hours · Estimated delivery Jun 21 - Jun 26
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order